Microscope stand Axio Observer 5 - 6-position nosepiece, H DIC M27 cod. - manual focus drive incl. focus stop - z-drive operation, flat; left - 1x tube lens to fit with optional available 1-position tube lens mount or 3-position optovar turret cod. - slider mount for PlasDIC and analyzer module - circular operation key unit right - keys for switching TL/RL illumination - light manager - interfaces: 1x CAN, 2x USB-A, 1x USB-C and 1x TCP/IP - trigger socket (In/Out) for shutter - connecting socket for external UNIBLITZ shutter - integrated 12V DC 100W power supply, stabilized, 100V-127V and 200V-240VAC / 50-60Hz / max. 300VA - USB cable and country-specific line cable
项目编号:
431006-9901-000
1-position tube lens mount, fixed
1-position tube lens mount, fixed
项目编号:
431010-0000-000
1-position tube lens mount, fixed
项目编号:
431010-0000-000
Aqua Stop II
Aqua Stop II
项目编号:
431716-0000-000
Aqua Stop II for Axio Observer, Axiovert 5 and Axiovert 200
项目编号:
431716-0000-000
Path deflection to the tube
Path deflection to the tube
项目编号:
000000-1069-227
Path deflection to the tube for visual observation
项目编号:
000000-1069-227
Sideport 60N L, 3 switching positions
Sideport 60N L, 3 switching positions
项目编号:
425152-0000-000
Sideport 60N L, 3 switching positions (100% vis : 0% L / 0% vis : 100% L / 50% vis : 50% L)
Microscope stand Axio Observer 5 - 6-position nosepiece, H DIC M27 cod. - manual focus drive incl. focus stop - z-drive operation, flat; left - 1x tube lens to fit with optional available 1-position tube lens mount or 3-position optovar turret cod. - slider mount for PlasDIC and analyzer module - circular operation key unit right - keys for switching TL/RL illumination - light manager - interfaces: 1x CAN, 2x USB-A, 1x USB-C and 1x TCP/IP - trigger socket (In/Out) for shutter - connecting socket for external UNIBLITZ shutter - integrated 12V DC 100W power supply, stabilized, 100V-127V and 200V-240VAC / 50-60Hz / max. 300VA - USB cable and country-specific line cable
项目编号:
431006-9901-000
1-position tube lens mount, fixed
1-position tube lens mount, fixed
项目编号:
431010-0000-000
1-position tube lens mount, fixed
项目编号:
431010-0000-000
Sideport 60N L, 3 switching positions
Sideport 60N L, 3 switching positions
项目编号:
425152-0000-000
Sideport 60N L, 3 switching positions (100% vis : 0% L / 0% vis : 100% L / 50% vis : 50% L)
项目编号:
425152-0000-000
Path deflection to the tube
Path deflection to the tube
项目编号:
000000-1069-227
Path deflection to the tube for visual observation
项目编号:
000000-1069-227
Aqua Stop II
Aqua Stop II
项目编号:
431716-0000-000
Aqua Stop II for Axio Observer, Axiovert 5 and Axiovert 200
Microscope stand Axio Observer 5 - 6-position nosepiece, H DIC M27 cod. - manual focus drive incl. focus stop - z-drive operation, flat; left - 1x tube lens to fit with optional available 1-position tube lens mount or 3-position optovar turret cod. - slider mount for PlasDIC and analyzer module - circular operation key unit right - keys for switching TL/RL illumination - light manager - interfaces: 1x CAN, 2x USB-A, 1x USB-C and 1x TCP/IP - trigger socket (In/Out) for shutter - connecting socket for external UNIBLITZ shutter - integrated 12V DC 100W power supply, stabilized, 100V-127V and 200V-240VAC / 50-60Hz / max. 300VA - USB cable and country-specific line cable
项目编号:
431006-9901-000
3-position Optovar turret cod.
3-position Optovar turret cod.
项目编号:
431012-0000-000
3-position Optovar turret cod.
项目编号:
431012-0000-000
Sideport 60N L, 3 switching positions
Sideport 60N L, 3 switching positions
项目编号:
425152-0000-000
Sideport 60N L, 3 switching positions (100% vis : 0% L / 0% vis : 100% L / 50% vis : 50% L)
项目编号:
425152-0000-000
Path deflection to the tube
Path deflection to the tube
项目编号:
000000-1069-227
Path deflection to the tube for visual observation
项目编号:
000000-1069-227
Anti vibration set Axio Observer (D)
Anti vibration set Axio Observer (D)
项目编号:
431007-9000-000
Anti vibration set Axio Observer (D) Comprising: 2 supporting plates, fitted with 2 vibration dampers (each), for the fixed mounting at the bottom of the Axio Observer stand
Carrier for transmitted-light illumination with LCD display
Carrier for transmitted-light illumination with LCD display
项目编号:
423922-0000-000
Carrier for transmitted-light illumination with LCD display and light manager, carrier tiltable, for the mounting of condensers. Equipped with luminous-field diaphragm, 3-position filter changer and attachment possibility for micromanipulators. LCD display, four lines for display of nosepiece position, objective magnification, contrasting techniques, reflector turret equipment and lamp brightness.
Carrier for transmitted-light illumination with LCD display
Carrier for transmitted-light illumination with LCD display
项目编号:
423922-0000-000
Carrier for transmitted-light illumination with LCD display and light manager, carrier tiltable, for the mounting of condensers. Equipped with luminous-field diaphragm, 3-position filter changer and attachment possibility for micromanipulators. LCD display, four lines for display of nosepiece position, objective magnification, contrasting techniques, reflector turret equipment and lamp brightness.
Illuminator microLED 3 for mounting on the lamp interface for transmitted-light or reflected-light illumination - colour temperature 5700 K - colour rendering index >90
Illuminator microLED 3 for mounting on the lamp interface for transmitted-light or reflected-light illumination - colour temperature 5700 K - colour rendering index >90
项目编号:
423053-9074-000
Illumination adapter for light guide (D)
Illumination adapter for light guide (D)
项目编号:
423302-0000-000
Illumination adapter for light guide (D) Suitable for HXP 120 and X-Cite 120, coupling diameter of light guide 5 mm
项目编号:
423302-0000-000
Illuminator HXP 120 V (D)
Illuminator HXP 120 V (D)
项目编号:
423013-9010-000
Illuminator HXP 120 V (D) inclusive built in power supply, lamp module and infrared filter. Fluorescence light source with motorized brightness switch and integrated motorized shutter, that works stepper motor controlled, fast and vibration free. With CAN connection for switching the shutter and the motorized brightness switch via ZEN (blue edition) and ZEN 2 (black edition). Interfaces: - 1x CAN (CAN-HD15) - 1x Trigger in (BNC) - 1x Trigger out (BNC) - 1x EXT (BNC) for remote control unit The package includes light guide, cable BNC and cable CAN.
Illuminator microLED 3 for mounting on the lamp interface for transmitted-light or reflected-light illumination - colour temperature 5700 K - colour rendering index >90
项目编号:
423053-9074-000
Light Source Viluma 5 RGB-UV
Light Source Viluma 5 RGB-UV
项目编号:
423052-9641-000
Light Source Viluma 5 RGB-UV 4-channel fluorescence light source with integrated control unit for continuous brightness adjustment, quickly switchable. Equipped with 4 solid state LED lamps. Red (631 nm) for excitation of Cy5, Alexa 631, TOTO-3 and similar dyes Green (555 nm) for excitation of Cy3, TRITC, DsRed and similar dyes Blue (469 nm) for excitation of eGFP, Fluo4, FITC and similar dyes UV (385 nm) for excitation of DAPI, Alexa 405, Hoechst 33258 and similar dyes A country-specific power cableand a desktop power supply are included in delivery. When used at an Axio Observer with Incubator XLmulti, the Extension tube for illuminator mount, 17 mm is required.
Conversion filter 5700-3200 K, d=32 mm for adapting the LED light to the color impression of halogen light
项目编号:
427809-9000-000
Filter set 49 DAPI shift free (E)
Filter set 49 DAPI shift free (E)
项目编号:
488049-9901-000
Filter set 49 DAPI shift free (E) EX G 365, BS FT 395, EM BP 445/50
项目编号:
488049-9901-000
Filter set 50 Cy 5 shift free (E)
Filter set 50 Cy 5 shift free (E)
项目编号:
488050-9901-000
Filter set 50 Cy 5 shift free (E) EX BP 640/30, BS FT 660, EM BP 690/50, recommended for white light fluorescence light sources or ZEISS LED fluorescence light sources.
项目编号:
488050-9901-000
Filter set 45 HQ TexasRed, d=25 shift free (E)
Filter set 45 HQ TexasRed, d=25 shift free (E)
项目编号:
000000-1114-462
Filter set 45 HQ TexasRed, d=25 shift free (E) EX BP 560/40, BS FT 585, EM BP 630/75, recommended for white light fluorescence light sources or ZEISS LED fluorescence light sources.
项目编号:
000000-1114-462
Filter set 43 Cy 3, d=25 shift free (E)
Filter set 43 Cy 3, d=25 shift free (E)
项目编号:
000000-1114-101
Filter set 43 Cy 3, d=25 shift free (E) EX BP 545/25, BS FT 570, EM BP 605/70, recommended for white light fluorescence light sources or ZEISS LED fluorescence light sources.
项目编号:
000000-1114-101
Filter set 38 Endow GFP shift free (E)
Filter set 38 Endow GFP shift free (E)
项目编号:
000000-1031-346
Filter set 38 Endow GFP shift free (E) EX BP 470/40, BS FT 495, EM BP 525/50, recommended for white light fluorescence light sources or ZEISS LED fluorescence light sources.
Conversion filter 5700-3200 K, d=32 mm for adapting the LED light to the color impression of halogen light
项目编号:
427809-9000-000
Filter set 90 HE LED (E)
Filter set 90 HE LED (E)
项目编号:
489090-9110-000
Filter set 90 HE LED (E) for use with ZEISS LED fluorescence light sources. Suitable for fluorescent dyes like DAPI, FITC, TRITC and Cy5 with excitation wavelengths 385, 475, 555 and 630 nm. Contains beam splitter QBS 405 + 493 + 575 + 653 and emission filter QBP 425/30 + 514/30 + 592/25 + 709/100.
Shutter FL, internal for stands Axio Observer 3 / 5 / 7 / D1 / Z1 for reflected-light illumination switching time < 60 ms switching frequency max. 5 Hz
项目编号:
423625-0000-000
Antiglare screen for Axio Observer/Axiovert 200
Antiglare screen for Axio Observer/Axiovert 200
项目编号:
000000-1109-741
Antiglare screen for Axio Observer/Axiovert
项目编号:
000000-1109-741
Iris stop slider for incident-light equipment
Iris stop slider for incident-light equipment
项目编号:
000000-1062-360
Iris stop slider for incident-light equipment centerable, can be used as luminous-field diaphragm and/or aperture diaphragm slider (Köhler-type illumination in incident-light beam path)
项目编号:
000000-1062-360
Reflector module FL EC P&C
Reflector module FL EC P&C
项目编号:
424931-0000-000
Reflector module FL EC P&C Reflection avoided through tilted mount for emission filters, max. filter thickness: 5 mm
Shutter FL, internal for stands Axio Observer 3 / 5 / 7 / D1 / Z1 for reflected-light illumination switching time < 60 ms switching frequency max. 5 Hz
项目编号:
423625-0000-000
Antiglare screen for Axio Observer/Axiovert 200
Antiglare screen for Axio Observer/Axiovert 200
项目编号:
000000-1109-741
Antiglare screen for Axio Observer/Axiovert
项目编号:
000000-1109-741
Iris stop slider for incident-light equipment
Iris stop slider for incident-light equipment
项目编号:
000000-1062-360
Iris stop slider for incident-light equipment centerable, can be used as luminous-field diaphragm and/or aperture diaphragm slider (Köhler-type illumination in incident-light beam path)
项目编号:
000000-1062-360
Reflector module FL EC P&C
Reflector module FL EC P&C
项目编号:
424931-0000-000
Reflector module FL EC P&C Reflection avoided through tilted mount for emission filters, max. filter thickness: 5 mm
Slider assembly Apotome 3 for Axio Observer consisting of: slider with control electronics and transmission grids with 3 frequencies, reflector module calibration Apotome ACR P&C for LED and white light source, mirror and fluorescence test slides, cable CAN-BUS, case.
Microscopy Camera Axiocam 807 mono (D) High performance microscopy monochrome camera incl. driver software 64bit, Interface card USB 3.1 Gen2 PCIe x4, dual USB 3.0 cable 3 m - Sensor Type: CMOS, monochrome, Global Shutter, Sony IMX420 - Number of Pixels: 3216 (H) x 2208 (V) = 7.1 Mega Pixels - Pixel Size: 4.5 µm x 4.5 µm - Chip Size: 14.5 mm x 9.9 mm, equivalent to 1.1" (17,6 mm diagonal) - Spectral Range: With protection glass, 350 nm to 1000 nm - Peak QE: 78% @ 520 nm (typ.) - Full Well Capacity: Approx. 25,000 e- at gain 1x (typ.) - Adjustable Signal Amplification: 1x, 2x, 4x, 8x, 16x Selectable Resolution: H x V Binning Factor (digital) 3216 x 2208 1x1 basic pixel count 1608 x 1104 2x2 1072 x 991 3x3 884 x 743 4x4 643 x 594 5x5 (at 2x2 combined analog and digital binning for further increase of sensitivity) H x V Subsampling Factor (full field of view) 3216x2208 1x1 1608 x 1104 2x2 Live frame rates (depending on hardware and software configuration): Exp. Time 1ms H x V Frame Rate 3216 x 2208 >30 fps (High Res mode) 1602 x 1104>30 fps (Fast Mode, reduced CPU load) Frame rates for time series recording (1 ms exposure, further depending on sensor ROI, hardware and software configuration) H x V (ROI) Frame Rate (fps) 3216 x 2208 73 1929 x 1080 145 1608 x 1104 260 (2x2 subsamp. full field of view) 1024 x 1024 151 512 x 512 282 1920 x 256 487 Read Noise Full Well Capacity Dynamic Range (at gain) 5.7 e (1x) 25,000 e 1:4420 4.6 e (2x) 12,500 e 1:2730 3.9 e (4x) 6,250 e 1:1610 3.4 e (8x) 3,125 e 1:930 2.9 e (16x) 1,500 e 1:530 Low Noise Mode: 4.0 e 25,000 e 1:25,000 Software Supported Camera Operation: - Exposure time adjustment with continuous, automatic or manual mode, - Adjustable over or under-exposure mode, - Optional measurement on defined target area (spot-meter), - Image sharpening, - Dark current compensation, - Single pixel noise correction - Readout of Sensor Sub Regions ("ROI"): Adjustable - Digitization: 8, 12, 14 bit / pixel (8 out of 14 bit or compression mode) - Dark Current: < 0.3 e/p/s @ 25 °C sensor temperature - Cooling: Stabilized temperature to 25 °C (mounted on microscope, free air flow, ambient temp. 22 °C) - Exposure Time Range: 0.1 ms to 60 s - Hardware Trigger: Trigger-In for exposure time control Trigger-Out for exposure time Readout time and trigger ready status (further accessories required) - Status-LED for Camera: Color coded operation status, dimmable - Camera Interface: Dual USB 3.0 SuperSpeed, 2 x 5 Gbit/s for data and power supply (optional single USB 3.0 at lower frame rates and without cooling) - Optical Interface: C-Mount - Thread Depth for Objectives: Max. 5mm - Size / Weight: Approx. 10.8 cm x 7.8 cm x 6.1 cm (4.2"x 3.1" x 2.4")/ 620 g - Housing: Blue anodized aluminum, with cooling fins on top 1/4" photo thread for tripod mount - Registration: CE - Power Supply: Provided by Dual USB 3.0, 5V, max. 7 W power consumption - Environmental Conditions: 5 °C to 35 °C, max.80% relative air humidity, not condensing, free air circulation required Supported Operating Systems: for ZEN: Windows 10 / Windows 11 Supported Application Software: ZEN 3.6 (blue edition) or higher, ZEN 3.5 core or higher The required application software is provided via ZEISS Microscopy Installer or ZEISS Download Center.
ZEN 3.11 Image acquisition and processing under Windows 10 / Windows 11 x64 User interface configurable, control of the ZEISS microscope systems and components, extensive acquisition and analysis, CZI image format The following functions are included: - Basic 3D viewing - Colocalization - Connect basic - Direct processing - Manual EDF - Measurement - Panorama - Spectral unmixing - ZEN Data Storage Client - Acquisition Base (time series and multichannel)