Axiovert 5
Inverted microscope Axiovert 5 TL SCB f/Ph1 PlasDIC
Item no.: 491237-0024-000 (individual configuration)Inverted microscope Axiovert 5 TL SCB for transmitted-light brightfield, phase contrast Ph1 and Plas...
Inverted microscope Axiovert 5 TL SCB f/Ph1 PlasDIC
Item Number: 491237-0024-000 (individual configuration) Reset configurationTip
Current configuration
-
Microscope stand Axiovert 5 TL SCB
Item no.: 431030-9120-000Microscope stand Axiovert 5 TL SCB
Item Number: 431030-9120-000Microscope stand Axiovert 5 TL SCB with integrated Smart Control Box - 6-position nosepiece B DIC M27, encoded with 10x29 mm slider mount - Carrier transmitted-light with integrated white LED 10W (average LED lifetime > 60000 hrs) and 2-position filter slider, d=32 mm - manual coarse/fine focus drive - 13 mm focus lift with adjustable focus stop - snap button for ZEISS Axiocam - ECO mode - Light manager - Smart Control Box - for stand-alone operation (without PC) of microscope stand functions with ZEISS Axiocam (105 R2, 202, 208, 305, 705) via On Screen Display and for usage with Labscope (Windows and iOS) - Automatic features for camera control, Image enhancement functions and readout of encoded microscope functions - Provided interfaces: HDMI, USB3.0 Type C and Type A, USB 2.0 Type A, Ethernet, Micro-D - Wi-Fi compatibility via USB Wi-Fi adapter and router - USB 3.0 flash drive, Type-C and Type-A - USB 3.0 cable 0.5 m for Axiocam 305 - USB 2.0, Type B interface to PC - external power adaptor input: 100-240V AC, 50/60Hz output: 24VDC,5A - country specific power cable - Dust protection set
-
Intermediate phototube H=50mm, left port
Item no.: 425146-9031-000Intermediate phototube H=50mm, left port
Item Number: 425146-9031-000Intermediate phototube H=50mm, left port - Camera port with interface 60N - Slider mount with 2 clickstop positions Additionally required: - Slider with mirror 100% - Slider with beam splitter 50% - Slider with beam splitter 20/80%
-
Slider with Beam Splitter 50% for Intermediate Phototube
Item no.: 425146-9061-000Slider with Beam Splitter 50% for Intermediate Phototube
Item Number: 425146-9061-000Slider with Beam Splitter 50% for Intermediate Phototube - 2 clickstop positions for 100vis/50vis:50doc
-
PlasDIC module LD A-Plan 10x-63x for contrast slider 10x29 mm
Item no.: 426980-9040-000PlasDIC module LD A-Plan 10x-63x for contrast slider 10x29 mm
Item Number: 426980-9040-000PlasDIC module LD A-Plan 10x-63x for contrast slider 10x29 mm
-
Slit diaphragm 3.5 mm PlasDIC for slider (10x-40x)
Item no.: 426717-9330-000Slit diaphragm 3.5 mm PlasDIC for slider (10x-40x)
Item Number: 426717-9330-000Slit diaphragm 3.5 mm PlasDIC for slider (10x-40x)
-
Specimen stage 232x230 mm with hardcoat anodized surface
Item no.: 432037-9000-000Specimen stage 232x230 mm with hardcoat anodized surface
Item Number: 432037-9000-000Specimen stage 232x230 mm with hardcoat anodized surface - Object guide M mountable on both sides
-
Mounting frame Flex M
Item no.: 432333-9030-000Mounting frame Flex M
Item Number: 432333-9030-000Mounting frame Flex M - for microwell plates, flasks and petridishes d=95 mm - for the mounting of Mounting frame inserts Flex M
-
Mounting frame insert Flex M, petridishes
Item no.: 432333-9050-000Mounting frame insert Flex M, petridishes
Item Number: 432333-9050-000Mounting frame insert Flex M, petridishes - for petridishes d=88 mm, 65 mm, 54 mm, 36 mm - for insertion in Mounting frame Flex M
-
Mounting frame insert Flex M, slides and chambers
Item no.: 432333-9060-000Mounting frame insert Flex M, slides and chambers
Item Number: 432333-9060-000Mounting frame insert Flex M, slides and chambers - for object slides 76x26 mm - for chambers (ibidi® µ-SlideTM, Nunc® Lab-TekTM / Lab-TekTM II) - for insertion in Mounting frame Flex M
-
Object guide M 130x85 R/L for Axiovert
Item no.: 432333-9100-000Object guide M 130x85 R/L for Axiovert
Item Number: 432333-9100-000Object guide M 130x85 R/L for Axiovert - for Axiovert 5/7 and Axio Vert.A1 - for mounting frames M - mountable on both sides without tools
-
Binocular tube 45°/23
Item no.: 425523-9000-000Binocular tube 45°/23
Item Number: 425523-9000-000Binocular tube 45°/23 - upright and unreversed image
-
Conversion filter 5700-3200 K, d=32 mm
Item no.: 427809-9000-000Conversion filter 5700-3200 K, d=32 mm
Item Number: 427809-9000-000Conversion filter 5700-3200 K, d=32 mm for adapting the LED light to the color impression of halogen light
-
Green filter, d=32x2 mm
Item no.: 000000-1374-896Green filter, d=32x2 mm
Item Number: 000000-1374-896Green filter, d=32x2 mm for contrast enhancement for phase contrast and b/w image recording
-
Camera Adapter 60N-C 2/3" 0.5x
Item no.: 426112-0000-000Camera Adapter 60N-C 2/3" 0.5x
Item Number: 426112-0000-000Camera Adapter 60N-C 2/3" 0.5x
-
Eyepiece PL 10x/23 Br. foc.
Item no.: 444036-9000-000Eyepiece PL 10x/23 Br. foc.
Item Number: 444036-9000-000Eyepiece PL 10x/23 Br. foc.
-
Eyepiece eyecup
Item no.: 444801-0000-000Eyepiece eyecup
Item Number: 444801-0000-000Eyepiece eyecup
-
Objective LD A-Plan 40x/0.55 Ph1 M27
Item no.: 421261-9917-000Objective LD A-Plan 40x/0.55 Ph1 M27
Item Number: 421261-9917-000Objective LD A-Plan 40x/0.55 Ph1 M27 (FWD=2.3mm at CG=1mm polystyrene)
-
Objective LD A-Plan 20x/0.35 Ph1 M27
Item no.: 421251-9911-000Objective LD A-Plan 20x/0.35 Ph1 M27
Item Number: 421251-9911-000Objective LD A-Plan 20x/0.35 Ph1 M27 (FWD=4.9mm at CG=1mm polystyrene)
-
Objective LD A-Plan 10x/0.25 Ph1 M27
Item no.: 421241-9910-000Objective LD A-Plan 10x/0.25 Ph1 M27
Item Number: 421241-9910-000Objective LD A-Plan 10x/0.25 Ph1 M27 (FWD=8.5mm at CG=1mm polystyrene)
-
LD condenser 0.4 for slider
Item no.: 424228-9020-000LD condenser 0.4 for slider
Item Number: 424228-9020-000LD condenser 0.4 for slider - for H, Ph, PlasDIC - rotatable, with click stops 0°, 90°, 180°, 270° - for objectives 5x - 63x (2.5x with diffusion disk 2.5x) - 10x46 mm slider mount - 53 mm working distance - aperture stop
-
Slider 10x46 mm Ph/PlasDIC, H, Ph/PlasDIC
Item no.: 426717-9000-000Slider 10x46 mm Ph/PlasDIC, H, Ph/PlasDIC
Item Number: 426717-9000-000Slider 10x46 mm Ph/PlasDIC, H, Ph/PlasDIC - 2 positions for Ph- or PlasDIC diaphragms - brightfield position with neutral-density filter 0.06
-
3 position contrast slider 10x29 mm for PlasDIC module and analyzer
Item no.: 426980-9050-0003 position contrast slider 10x29 mm for PlasDIC module and analyzer
Item Number: 426980-9050-0003 position contrast slider 10x29 mm for PlasDIC module and analyzer
-
Phase stop Ph 1/0.4 for slider
Item no.: 426717-9350-000Phase stop Ph 1/0.4 for slider
Item Number: 426717-9350-000Phase stop Ph 1/0.4 for slider
-
Microscopy Camera Axiocam 305 color (D)
Item no.: 426560-9030-000Microscopy Camera Axiocam 305 color (D)
Item Number: 426560-9030-000Microscopy Camera Axiocam 305 color (D) Microscopy camera incl. Driver software 64bit, USB 3.0 PCIe x1 interface, USB 3.0 cable 3 m and IR barrier filter Hoya C5000 (coated) Number of Pixels: 2464 (H) x 2056 (V) = 5.07 Mega pixel color Sensor type: SONY IMX264 Exmor Pregius Global Shutter CMOS Pixel size: 3.45 #m x 3.45 #m Chip size: 8.5 mm x 7.1 mm, equivalent to 2/3" (diagonal 11.1 mm) Spectral range: With IR barrier filter app. 400 nm to 720 nm Full Well Capacity: Approx. 10,500 e Selectable Resolution: H x V Binning Factor 2464 x 2056 1x1 Basic Resolution 1232 x 1028 2x2 816 x 684 3x3 608 x 514 4x4 480 x 410 5x5 H x V Subsampling Factor 2464 x 2056 1x1 Basic Resolution 1232 x 1028 2x2 Live frame rates (depending on hardware and software configuration): H x V Frame Rate@1ms 2464 x 2056 36 fps 1232 x 1028 88 fps (2x2 Subsampling) Frame rates for time series recording (depending on computer hardware and software configuration) H x V (ROI) Frame Rate 2464 x 2056 36 fps 2048 x 2048 36 fps 1920 x 1080 67 fps 1024 x 1024 70 fps 512 x 512 136 fps 256 x 256 255 fps 128 x 128 456 fps Readout of Sensor Sub-Regions ("ROI"): Adjustable Digitization: 8 and 12 Bit / Pixel Dynamic Range: Typical > 4800 : 1 (>73 dB) at typ. 2.2 e readout noise Dark current: < 1.0 e/p/s @ 25°C Integration Time: 0.1 ms to to 4 s Cooling: Temperature stable @ 25°C for ambient temperatures between 18°C and 30°C Status-LED for Camera: color coded operation status, dimmable, Interface (camera): USB 3.0 interface Optional operation with USB 2.0 connection at reduced frame rate Optical Interface: C-Mount Thread depth for objectives: max. 5 mm Size / Weight: approx. App. 10.8 cm x 7.8 cm x 4.3 cm (2.3"x3.2"x1.7") / 580 g Housing: blue anodized aluminum, with cooling fins on top, 1/4" photo thread for tripod mount Registration: CE Power Supply: Max. 4W, power supply provided by USB 3.0 bus for camera electronics Environmental conditions: 5° … +35° Celsius, max 80% relative air humidity, not condensing, free air circulation required Supported Operating Systems: for ZEN: Windows 10 x64 for Labscope: Windows 10 x64 Supported Application Software: ZEN 2.3 (blue edition) or higher, ZEN core v2.5 or higher Labscope v3.3 (Windows) or higher The required application software is available via the ZEISS Download Center.