- Carl Zeiss Shop
- Inverted microscopes
- Axio Vert.A1
- Inverted microscope Axio Vert.A1

Axio Vert.A1
Axio Vert.A1
Axio Vert.A1
Axio Vert.A1
Axio Vert.A1
Axio Vert.A1
ZEISS Axio Vert.A1 - Product Trailer
Inverted microscope Axio Vert.A1
Item no.: 491237-0006-000 (individual configuration)Inverted microscope Axio Vert.A1 for transmitted-light brightfield HAL, phase contrast Ph1 and PlasD...
Inverted microscope Axio Vert.A1
Item Number: 491237-0006-000 (individual configuration) Reset configurationTip
Current configuration
-
Microscope stand Axio Vert.A1
Item no.: 431030-9000-000Microscope stand Axio Vert.A1
Item Number: 431030-9000-000Microscope stand Axio Vert.A1 - 5-position nosepiece, H DIC M27 man. (2x H, 3x H DIC) with 10x29 mm slider mount - carrier transmitted-light illumination for HAL or LED with 2-position filter slider, d=32 mm - manual coarse/fine focus drive - 13 mm focus lift with adjustable focus stop - ergonomic intermediate piece H=50 mm - integrated 12V DC 60W power unit, stabilized, 100...240V AC/50...60Hz/80VA - country-specific power cable
-
Illuminator HAL for Axio Vert transmitted light
Item no.: 423004-9010-000Illuminator HAL for Axio Vert transmitted light
Item Number: 423004-9010-000Illuminator HAL for Axio Vert transmitted light
-
Bulb 12V 37W Halogen for Axio Vert
Item no.: 000000-1879-242Bulb 12V 37W Halogen for Axio Vert
Item Number: 000000-1879-242Bulb 12V 37W Halogen for Axio Vert
-
Slit diaphragm 3.5 mm PlasDIC for condenser (10x-40x)
Item no.: 426717-9110-000Slit diaphragm 3.5 mm PlasDIC for condenser (10x-40x)
Item Number: 426717-9110-000Slit diaphragm 3.5 mm PlasDIC for condenser (10x-40x)
-
Slit diaphragm 5 mm PlasDIC for condenser (40x/63x)
Item no.: 426717-9120-000Slit diaphragm 5 mm PlasDIC for condenser (40x/63x)
Item Number: 426717-9120-000Slit diaphragm 5 mm PlasDIC for condenser (40x/63x)
-
PlasDIC module LD A-Plan 10x-63x for contrast slider 10x29 mm
Item no.: 426980-9040-000PlasDIC module LD A-Plan 10x-63x for contrast slider 10x29 mm
Item Number: 426980-9040-000PlasDIC module LD A-Plan 10x-63x for contrast slider 10x29 mm
-
Mechanical stage 130x85 R/L with short coaxial drive
Item no.: 432047-9902-000Mechanical stage 130x85 R/L with short coaxial drive
Item Number: 432047-9902-000Mechanical stage 130x85 R/L with short coaxial drive for mounting frames K 160 x 110 mm and Z-PIEZO, particularly recommended in combination with lateral camera port, compatible with objectives autocorr
-
Binocular phototube, left port 45°/23 (50:50)
Item no.: 425523-9020-000Binocular phototube, left port 45°/23 (50:50)
Item Number: 425523-9020-000Binocular phototube, left port 45°/23 (50:50) - upright and unreversed image - camera port with interface 60N
-
Green filter, d=32x2 mm
Item no.: 000000-1374-896Green filter, d=32x2 mm
Item Number: 000000-1374-896Green filter, d=32x2 mm for contrast enhancement for phase contrast and b/w image recording
-
Neutral-density filter 0.05 for condenser
Item no.: 424228-9060-000Neutral-density filter 0.05 for condenser
Item Number: 424228-9060-000Neutral-density filter 0.05 for condenser - for the use at transmitted-light brightfield with alternating Ph, PlasDIC, iHMC - to be inserted into free position of LD condensers with modulator disk
-
Eyepiece PL 10x/23 Br. foc.
Item no.: 444036-9000-000Eyepiece PL 10x/23 Br. foc.
Item Number: 444036-9000-000Eyepiece PL 10x/23 Br. foc.
-
Eyepiece eyecup
Item no.: 444801-0000-000Eyepiece eyecup
Item Number: 444801-0000-000Eyepiece eyecup
-
Objective LD A-Plan 63x/0.65 for Thermo Plate M27
Item no.: 421280-9900-710Objective LD A-Plan 63x/0.65 for Thermo Plate M27
Item Number: 421280-9900-710Objective LD A-Plan 63x/0.65 for Thermo Plate M27 (FWD=1.1mm at CG=0.5mm glass + CG=1.0mm polystyrene)
-
Objective LD A-Plan 10x/0.25 Ph1 M27
Item no.: 421241-9910-000Objective LD A-Plan 10x/0.25 Ph1 M27
Item Number: 421241-9910-000Objective LD A-Plan 10x/0.25 Ph1 M27 (FWD=8.5mm at CG=1mm polystyrene)
-
Objective LD A-Plan 20x/0.35 Ph1 M27
Item no.: 421251-9911-000Objective LD A-Plan 20x/0.35 Ph1 M27
Item Number: 421251-9911-000Objective LD A-Plan 20x/0.35 Ph1 M27 (FWD=4.9mm at CG=1mm polystyrene)
-
Objective LD A-Plan 40x/0.55 Ph1 for Thermo Plate M27
Item no.: 421261-9917-710Objective LD A-Plan 40x/0.55 Ph1 for Thermo Plate M27
Item Number: 421261-9917-710Objective LD A-Plan 40x/0.55 Ph1 for Thermo Plate M27 (FWD=1.5mm at CG=0.5mm glass + CG=1.0mm polystyrene)
-
LD condenser 0.4 for H Ph PlasDIC DIC iHMC
Item no.: 424228-9010-000LD condenser 0.4 for H Ph PlasDIC DIC iHMC
Item Number: 424228-9010-000LD condenser 0.4 for H Ph PlasDIC DIC iHMC - 5-position modulator disk, freely configurable - centerable positions, position 1 with aperture stop - for objectives 5x - 63x (2.5x with diffusion disk 2.5x) - 10x46 mm slider mount - 53 mm working distance
-
3 position contrast slider 10x29 mm for PlasDIC module and analyzer
Item no.: 426980-9050-0003 position contrast slider 10x29 mm for PlasDIC module and analyzer
Item Number: 426980-9050-0003 position contrast slider 10x29 mm for PlasDIC module and analyzer
-
Phase stop Ph 1 0.35/0.4 for condenser
Item no.: 426717-9150-000Phase stop Ph 1 0.35/0.4 for condenser
Item Number: 426717-9150-000Phase stop Ph 1 0.35/0.4 for condenser
-
Mounting Frame K Thermo Plate with Controller (D)
Item no.: 411860-9093-000Mounting Frame K Thermo Plate with Controller (D)
Item Number: 411860-9093-000Mounting Frame K Thermo Plate with Controller (D) - glass plate made of toughened glass - glass thickness: 0.5 mm (over entire glass plate surface) - LED status report - controller with LCD display: temperature range: room temperature to 50°C resolution: 0.1° C temperature accuracy: +/- 0.1°C 100V-240V AC/50-60Hz/max. 50VA - country specific power cable
-
Dust protection set for Axio Vert
Item no.: 434308-9000-000Dust protection set for Axio Vert
Item Number: 434308-9000-000Dust protection set for Axio Vert - dust cover (L520xW240xH470 mm) - eyepiece cover