Objective Assistant

Italiano EspaƱol
Print
Objective Assistant

List of Objectives

Brochure: Objectives from Carl Zeiss (5 MB)
|

Objectives Text Search

Objective Class Magnific. Contrast Method/Application Options AND  OR
For multiple selection: hold [PC: 'Ctrl'-key] [Mac: 'Command'-key] down.
Search result for "Phase Contrast": 49 Objectives
Magnification   Product Name Objective Properties
Objective A-Plan 5x/0.12 Ph0 M27
421031-9910-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

5x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0.12 10.1 0.17
Price Basket Compare (max. 4)
Objective N-Achroplan 5x/0.13 Ph0 M27
420931-9910-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

5x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0.13 5.5 0.17
Price Basket Compare (max. 4)
Objective EC Plan-Neofluar 5x/0.16 Ph1 M27
420331-9911-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

5x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0.16 18.5 0.17
Price Basket Compare (max. 4)
Objective LD A-Plan 5x/0.15 Ph1 M27
421231-9910-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

5x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0.15 11.7 1.0
Price Basket Compare (max. 4)
Objective N-Achroplan 5x/0.15 Ph1 M27
420931-9911-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

5x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0.15 12.0 0.17
Price Basket Compare (max. 4)
Objective N-Achroplan 10x/0.25 Ph1 M27
420941-9910-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

10x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0.25 6.0 0.17
Price Basket Compare (max. 4)
Objective Plan-Apochromat 10x/0.45 Ph1 M27
420641-9910-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

10x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0.45 2.0 0.17
Price Basket Compare (max. 4)
Objective A-Plan 10x/0.25 Ph1 M27
421041-9910-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

10x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0.25 4.3 0.17
Price Basket Compare (max. 4)
Objective A-Plan 10x/0.25 Ph1- M27
421041-9910-710
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

10x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0.25 4.2 0.17
Price Basket Compare (max. 4)
Objective EC Plan-Neofluar 10x/0.3 Ph1 M27
420341-9911-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

10x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0.3 5.2 0.17
Price Basket Compare (max. 4)
Objective LD A-Plan 10x/0.25 Ph1 M27
421241-9910-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

10x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0.25 8.5 1.0
Price Basket Compare (max. 4)
Objective N-Achroplan 10x/0.25 Ph1 M27
420941-9911-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

10x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0.25 6.5 0.17
Price Basket Compare (max. 4)
Objective A-Plan 20x/0.45 Ph2 M27
421051-9910-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

20x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0.45 0.46 0.17
Price Basket Compare (max. 4)
Objective Plan-Apochromat 20x/0.8 Ph2 M27
420651-9911-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

20x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0.8 0.55 0.17
Price Basket Compare (max. 4)
Objective EC Plan-Neofluar 20x/0.50 Ph2 M27
420351-9910-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

20x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0.5 2.0 0.17
Price Basket Compare (max. 4)
Objective LD A-Plan 20x/0.3 Ph1
441241-9911-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

20x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0.3 4.2 at cover glass 1.0 0-2
Price Basket Compare (max. 4)
Objective LD Plan-Neofluar 20x/0.4 Corr Ph1 Ph2- M27
421351-9970-710
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

20x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0.4 7.9 at cover glass 0.75 0-1.5
Price Basket Compare (max. 4)
Objective LD Plan-Neofluar 20x/0.4 Corr Ph2 M27
421351-9970-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

20x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0.4 7.9 at cover glass 0.75 0-1.5
Price Basket Compare (max. 4)
Objective LD A-Plan 20x/0.35 Ph1 M27
421251-9911-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

20x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0.35 4.9 1.0
Price Basket Compare (max. 4)
Objective LD A-Plan 20x/0.35 Ph1- M27
421251-9910-710
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

20x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0.35 4.3 1.0
Price Basket Compare (max. 4)
Objective LD A-Plan 20x/0.35 Ph2 M27
421251-9911-711
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

20x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0.35 4.9 1.0
Price Basket Compare (max. 4)
Objective N-Achroplan 20x/0.45 Ph2 M27
420951-9911-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

20x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0.45 0.65 0.17
Price Basket Compare (max. 4)
Objective LCI Plan-Neofluar 25x/0.8 Imm Corr Ph2 M27
420851-9972-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

25x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0.8 0.21 at cover glass 0.17 0-0.17
Price Basket Compare (max. 4)
Objective LD A-Plan 32x/0.45 Ph1 M27
421261-9910-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

32x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0.45 3.1 1.0
Price Basket Compare (max. 4)
Objective A-Plan 40x/0.65 Ph2 M27
421061-9910-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

40x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0.65 0.45 0.17
Price Basket Compare (max. 4)
Objective A-Plan 40x/0.65 Ph2 Var2
441051-9922-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

40x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0.65 0.45 0.17
Price Basket Compare (max. 4)
Objective Plan-Apochromat 40x/0.95 Corr Ph3 M27
420661-9970-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

40x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0.95 0.25 0.13-0.21
Price Basket Compare (max. 4)
Objective Plan-Apochomat 40x/1.3 Oil Ph3 M27
420761-9810-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

40x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
1.3 0.21 0.17
Price Basket Compare (max. 4)
Objective CP-"Achromat" 40x/0.65 Ph2
440951-0000-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

40x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0.65 0.38 0.17
Price Basket Compare (max. 4)
Objective EC Plan-Neofluar 40/1.30 Oil Ph3 M27
420461-9910-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

40x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
1.3 0.21 0.17
Price Basket Compare (max. 4)
Objective EC Plan-Neofluar 40x/0.75 Ph2 M27
420361-9910-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

40x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0.75 0.71 0.17
Price Basket Compare (max. 4)
Objective LD Plan-Neofluar 40x/0.6 Corr Ph1 Ph2- M27
421361-9970-710
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

40x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0.6 2.9 at cover glass 0.75 0-1.5
Price Basket Compare (max. 4)
Objective LD Plan-Neofluar 40x/0.6 Corr Ph2 M27
421361-9970-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

40x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0.6 2.9 at cover glass 0.75 0-1.5
Price Basket Compare (max. 4)
Objective LD A-Plan 40x/0.55 Ph1 M27
421261-9917-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

40x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0.55 2.3 1.0
Price Basket Compare (max. 4)
Objective LD A-Plan 40x/0.55 Ph2 M27
421261-9918-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

40x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0.55 2.3 1.0
Price Basket Compare (max. 4)
Objective N-Achroplan 40x/0.65 Ph2 M27
420961-9911-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

40x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0.65 0.60 0.17
Price Basket Compare (max. 4)
Objective N-Achroplan 50x/1.0 Oil Ph3 M27
420971-9910-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

50x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
1.0 0.22 0-0.17
Price Basket Compare (max. 4)
Objective N-Achroplan 63x/0.85 Ph3 M27
420981-9910-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

63x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0.85 0.20 0.17
Price Basket Compare (max. 4)
Objective A-Plan 63x/0.8 Ph2 M27
421081-9910-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

63x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0.8 0.30 0.17
Price Basket Compare (max. 4)
Objective EC Plan-Neofluar 63x/1.25 Oil Ph3 M27
420481-9911-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

63x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
1.25 0.10 0.17
Price Basket Compare (max. 4)
Objective LCI Plan-Neofluar 63x/1.3 Imm Corr Ph3 M27
420881-9970-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

63x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
1.3 0.17 at cover glass 0.17 0.15-0.19
Price Basket Compare (max. 4)
Objective LD Plan-Neofluar 63x/0.75 Corr Ph2 M27
421381-9970-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

63x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0.75 1.7 at cover glass 0.75 0-1.5
Price Basket Compare (max. 4)
Objective LD A-Plan 63x/0.65 Ph2 M27
421281-9910-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

63x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0.65 1.8 1.0
Price Basket Compare (max. 4)
Objective Plan-Apochromat 63/1.4 Oil Ph3 M27
420781-9910-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

63x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
1.4 0.19 0.17
Price Basket Compare (max. 4)
Objective N-Achroplan 100x/1.25 Oil Ph3 M27
420991-9910-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

100x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
1.25 0.29 0.17
Price Basket Compare (max. 4)
Objective A-Plan 100x/1.25 Oil Ph2 M27
421091-9811-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

100x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
1.25 0.22 0.17
Price Basket Compare (max. 4)
Objective A-Plan 100x/1.25 Oil Ph3 M27
421091-9912-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

100x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
1.25 0.22 0.17
Price Basket Compare (max. 4)
Objective EC Plan-Neofluar 100x/1.30 Oil Ph3 M27
420491-9910-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

100x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
1.3 0.20 0.17
Price Basket Compare (max. 4)
Objective Plan-Apochromat 100x/1.4 Oil Ph3 M27
420791-9911-000
W0.8x1/36" thread M27x0.75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

100x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
1.4 0.17 0.17