Objective Assistant

Print
Objective Assistant

List of Objectives

Brochure: Objectives from Carl Zeiss (5 MB)
|

Objectives Text Search

Objective Class Magnific. Contrast Method/Application Options AND  OR
For multiple selection: hold [PC: 'Ctrl'-key] [Mac: 'Command'-key] down.
Search result for "Phase Contrast": 52 Objectives
Magnification   Product Name Objective Properties
Objective A-Plan 5x/0.12 Ph0 M27
421031-9910-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

5x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0,12 10,1 0,17
Price Basket Compare (max. 4)
Objective N-Achroplan 5x/0.13 Ph0 M27
420931-9910-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

5x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0,13 5,5 0,17
Price Basket Compare (max. 4)
Objective EC Plan-Neofluar 5x/0.16 Ph1 M27
420331-9911-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

5x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0,16 18,5 0,17
Price Basket Compare (max. 4)
Objective LD A-Plan 5x/0.15 Ph1 M27
421231-9910-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

5x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0,15 11,7 1,0
Price Basket Compare (max. 4)
Objective N-Achroplan 5x/0.15 Ph1 M27
420931-9911-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

5x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0,15 12,0 0,17
Price Basket Compare (max. 4)
Objective N-Achroplan 10x/0.25 Ph1 M27
420941-9910-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

10x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0,25 6,0 0,17
Price Basket Compare (max. 4)
Objective Plan-Apochromat 10x/0.45 Ph1 M27
420641-9910-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

10x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0,45 2,0 0,17
Price Basket Compare (max. 4)
Objective A-Plan 10x/0.25 Ph1 M27
421041-9910-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

10x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0,25 4,3 0,17
Price Basket Compare (max. 4)
Objective A-Plan 10x/0.25 Ph1- M27
421041-9910-710
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

10x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0,25 4,2 0,17
Price Basket Compare (max. 4)
Objective CP-"Achromat" 10x/0.25 Ph1
440931-0000-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

10x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0,25 5,1 0,17
Price Basket Compare (max. 4)
Objective EC Plan-Neofluar 10x/0.3 Ph1 M27
420341-9911-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

10x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0,3 5,2 0,17
Price Basket Compare (max. 4)
Objective LD A-Plan 10x/0.25 Ph1 M27
421241-9910-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

10x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0,25 8,5 1,0
Price Basket Compare (max. 4)
Objective N-Achroplan 10x/0.25 Ph1 M27
420941-9911-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

10x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0,25 6,5 0,17
Price Basket Compare (max. 4)
Objective A-Plan 20x/0.45 Ph2 M27
421051-9910-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

20x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0,45 0,46 0,17
Price Basket Compare (max. 4)
Objective Plan-Apochromat 20x/0.8 Ph2 M27
420651-9911-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

20x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0,8 0,55 0,17
Price Basket Compare (max. 4)
Objective EC Plan-Neofluar 20x/0.50 Ph2 M27
420351-9910-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

20x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0,5 2,0 0,17
Price Basket Compare (max. 4)
Objective LD A-Plan 20x/0.3 Ph1
441241-9911-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

20x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0,3 4,2 at cover glass 1,0 0-2
Price Basket Compare (max. 4)
Objective LD Plan-Neofluar 20x/0.4 Corr Ph1 Ph2- M27
421351-9970-710
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

20x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0,4 7,9 at cover glass 0,75 0-1,5
Price Basket Compare (max. 4)
Objective LD Plan-Neofluar 20x/0.4 Corr Ph2 M27
421351-9970-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

20x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0,4 7,9 at cover glass 0,75 0-1,5
Price Basket Compare (max. 4)
Objective LD A-Plan 20x/0.35 Ph1 M27
421251-9911-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

20x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0,35 4,9 1,0
Price Basket Compare (max. 4)
Objective LD A-Plan 20x/0.35 Ph1- M27
421251-9910-710
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

20x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0,35 4,3 1,0
Price Basket Compare (max. 4)
Objective LD A-Plan 20x/0.35 Ph2 M27
421251-9911-711
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

20x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0,35 4,9 1,0
Price Basket Compare (max. 4)
Objective N-Achroplan 20x/0.45 Ph2 M27
420951-9911-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

20x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0,45 0,65 0,17
Price Basket Compare (max. 4)
Objective LCI Plan-Neofluar 25x/0.8 Imm Corr Ph2 M27
420851-9972-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

25x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0,8 0,21 at cover glass 0,17 0-0,17
Price Basket Compare (max. 4)
Objective LD A-Plan 32x/0.4 Ph1 Var1
441251-9920-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

32x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0,4 3,2 at cover glass 1,0 0,6-1,4
Price Basket Compare (max. 4)
Objective LD A-Plan 32x/0.45 Ph1 M27
421261-9910-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

32x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0,45 3,1 1,0
Price Basket Compare (max. 4)
Objective A-Plan 40x/0.65 Ph2 M27
421061-9910-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

40x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0,65 0,45 0,17
Price Basket Compare (max. 4)
Objective A-Plan 40x/0.65 Ph2 Var2
441051-9922-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

40x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0,65 0,45 0,17
Price Basket Compare (max. 4)
Objective Plan-Apochromat 40x/0.95 Corr Ph3 M27
420661-9970-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

40x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0,95 0,25 0,13-0,21
Price Basket Compare (max. 4)
Objective Plan-Apochomat 40x/1.3 Oil Ph3 M27
420761-9810-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

40x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
1,3 0,21 0,17
Price Basket Compare (max. 4)
Objective CP-"Achromat" 40x/0.65 Ph2
440951-0000-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

40x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0,65 0,38 0,17
Price Basket Compare (max. 4)
Objective EC Plan-Neofluar 40/1.30 Oil Ph3 M27
420461-9910-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

40x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
1,3 0,21 0,17
Price Basket Compare (max. 4)
Objective EC Plan-Neofluar 40x/0.75 Ph2 M27
420361-9910-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

40x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0,75 0,71 0,17
Price Basket Compare (max. 4)
Objective LD Plan-Neofluar 40x/0.6 Corr Ph1 Ph2- M27
421361-9970-710
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

40x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0,6 2,9 at cover glass 0,75 0-1,5
Price Basket Compare (max. 4)
Objective LD Plan-Neofluar 40x/0.6 Corr Ph2 M27
421361-9970-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

40x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0,6 2,9 at cover glass 0,75 0-1,5
Price Basket Compare (max. 4)
Objective LD A-Plan 40x/0.55 Ph1 M27
421261-9917-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

40x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0,55 2,3 1,0
Price Basket Compare (max. 4)
Objective LD A-Plan 40x/0.55 Ph2 M27
421261-9918-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

40x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0,55 2,3 1,0
Price Basket Compare (max. 4)
Objective LD A-Plan 40x/0.55 Ph1 for Thermo Plate M27
421261-9917-710
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

40x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0,55 1,5 1,5
Price Basket Compare (max. 4)
Objective N-Achroplan 40x/0.65 Ph2 M27
420961-9911-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

40x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0,65 0,60 0,17
Price Basket Compare (max. 4)
Objective N-Achroplan 50x/1.0 Oil Ph3 M27
420971-9910-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

50x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
1,0 0,22 0-0,17
Price Basket Compare (max. 4)
Objective N-Achroplan 63x/0.85 Ph3 M27
420981-9910-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

63x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0,85 0,20 0,17
Price Basket Compare (max. 4)
Objective A-Plan 63x/0.8 Ph2 M27
421081-9910-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

63x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
0,8 0,30 0,17
Price Basket Compare (max. 4)
Objective EC Plan-Neofluar 63x/1.25 Oil Ph3 M27
420481-9911-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

63x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
1,25 0,10 0,17
Price Basket Compare (max. 4)
Objective LCI Plan-Neofluar 63x/1.3 Imm Corr Ph3 M27
420881-9970-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

63x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
1,3 0,17 at cover glass 0,17 0,15-0,19
Price Basket Compare (max. 4)
Objective LD Plan-Neofluar 63x/0.75 Corr Ph2 M27
421381-9970-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

63x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0,75 1,7 at cover glass 0,75 0-1,5
Price Basket Compare (max. 4)
Objective LD A-Plan 63x/0.65 Ph2 M27
421281-9910-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

63x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
LD 0,65 1,8 1,0
Price Basket Compare (max. 4)
Objective Plan-Apochromat 63/1.4 Oil Ph3 M27
420781-9910-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

63x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
1,4 0,19 0,17
Price Basket Compare (max. 4)
Objective N-Achroplan 100x/1.25 Oil Ph3 M27
420991-9910-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

100x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
1,25 0,29 0,17
Price Basket Compare (max. 4)
Objective A-Plan 100x/1.25 Oil Ph2 M27
421091-9811-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

100x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
1,25 0,22 0,17
Price Basket Compare (max. 4)
Objective A-Plan 100x/1.25 Oil Ph3 M27
421091-9912-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

100x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
1,25 0,22 0,17
Price Basket Compare (max. 4)
Objective EC Plan-Neofluar 100x/1.30 Oil Ph3 M27
420491-9910-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

100x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
1,3 0,20 0,17
Price Basket Compare (max. 4)
Objective Plan-Apochromat 100x/1.4 Oil Ph3 M27
420791-9911-000
W0,8x1/36" thread M27x0,75 thread BrightField DarkField Differential Interference Contrast DIC with circular polarized light PlasDIC Contrast Phase Contrast VAREL Contrast Polarization Contrast Fluorescence

Selection

100x Num. Aperture Free Work. Dist. [mm] Covergl. [mm]
1,4 0,17 0,17
Price Basket Compare (max. 4)